General information
The amplifier type ModMAG® M2000 is best suited for bidirectional flow measurement of fluids with a conductivity > 5 µS/cm (> 20 µS/cm for demineralized water). ModMAG® M2000 shows a high accuracy, is easy to use and can be chosen for a large and flexible applications spectrum.
The backlit, four-line display shows all actual flow measuring data, daily and complete information, including alarm messages.
The standard amplifier has 4 programmable digital outputs, one digital input, power output and USB interface. Integrated test tools make the putting into operation and the service easier.
Technical data
Size | DN 6 – DN 2000 |
Accuracy | ±0,2 % of actual flow, ±1 mm/s of actual flow |
Repeatability | 0,1 % |
Flow range | 0,03 – 12 m/s |
Conductivity | Min. 5 μS/cm (min. 20 μS/cm for demineralized water) |
Power supply | 85 – 265 VAC (50/60 Hz) < 20 VA, optional 9 – 36 VDC |
Display | LCD 4 lines / 20 characters |
Digital outputs | 4 x open collector, 2 x relays |
Digital inputs | Yes |
Analog output | 0/4 – 20 mA, 0/2 – 10 mA |
Interface | Modbus RTU RS232/RS485, Profibus DP, M-Bus, HART® |
Empty pipe detection | Separate electrode |
Datalogger | 10.000 measuring values (optional) |
Housing | Aluminium, IP 67 |
Remote version | Max. 100 m |
Ambient temperature | -20 °C up to +60 °C |
Approvals | OIML R49-1, MID MI-001 |