Language

Badger M2000 Electromagnetic Flow Meter(0.2%)

Construction:

General information

The amplifier type ModMAG® M2000 is best suited for bidirectional flow measurement of fluids with a conductivity > 5 µS/cm (> 20 µS/cm for demineralized water). ModMAG® M2000 shows a high accuracy, is easy to use and can be chosen for a large and flexible applications spectrum.

The backlit, four-line display shows all actual flow measuring data, daily and complete information, including alarm messages.

The standard amplifier has 4 programmable digital outputs, one digital input, power output and USB interface. Integrated test tools make the putting into operation and the service easier.

 

Technical data

Size

DN 6 – DN 2000

Accuracy

±0,2 % of actual flow,   ±1 mm/s of actual flow

Repeatability

0,1 %

Flow range

0,03 – 12 m/s

Conductivity

Min. 5 μS/cm (min. 20   μS/cm for demineralized water)

Power supply

85 – 265 VAC (50/60 Hz)   < 20 VA, optional 9 – 36 VDC

Display

LCD 4 lines / 20   characters

Digital outputs

4 x open collector, 2 x   relays

Digital inputs

Yes

Analog output

0/4 – 20 mA, 0/2 – 10   mA

Interface

Modbus RTU RS232/RS485,   Profibus DP, M-Bus, HART®

Empty pipe detection

Separate electrode

Datalogger

10.000 measuring values   (optional)

Housing

Aluminium, IP 67

Remote version

Max. 100 m

Ambient temperature

-20 °C up to +60 °C

Approvals

OIML R49-1, MID MI-001

 

Download