Badger M1000 Electromagnetic Flow Meter(0.3%)
Construction:
General information
The electromagnetic flow meter ModMAG® M1000 has been designed to fit into the MAG meter series and especially for applications in machinery plants, vehicles and batching processes.
The applications range from DN 6 to DN 500 with the most various process connections like DIN flanges, dairy pipe connections, TriClamp®, etc.
The basic line of ModMAG® M1000 is provided with 24 VDC power supply, without display, with passive outputs and can be programmed via a serial port RS 232 or separate handheld. The device can also, upon request, be factory preconfigured and then just needs to be electrically connected on site.
Technical Date
Size |
DN 6 – DN 500 |
Accuracy |
±0,3 % of actual flow, ±2 mm/s of actual flow |
Repeatability |
0,1 % |
Flow range |
0,03 – 12 m/s |
Conductivity |
Min. 5 μS/cm (min. 20 μS/cm for demineralized water) |
Power supply |
92 – 275 VAC (50/60 Hz) < 14 VA, optional 9 – 36 VDC, 4 W |
Display |
LCD graphic display |
Digital outputs |
2 x open collector, 1 x relay |
Digital inputs |
Yes |
Analog output |
0/4 – 20 mA, 0 – 10 mA |
Interface |
Modbus RTU RS232/RS485, ModBus®/TCP, M-Bus, HART® |
Empty pipe detection |
Separate electrode |
Datalogger |
30.000 measuring values |
Housing |
Aluminium, IP 67 |
Remote version |
Max. 50 m |
Ambient temperature |
-20 °C up to +60 °C |