01

Electromagnetic Flow/Energy Meters

M3000 Electromagnetic Flow Meter (Hazardous area "Zone 2" )

Download

 

Construction:

The ModMAG® M3000 Electromagnetic flow meter represents the next generation of magnetic-inductive measuring technology in the hazardous area "Zone 2" and is a precise and reliable measuring solution.

 

Technical Data:

Size

DN 6 – DN 600

Accuracy

± 0.20% of rate ± 1 mm/s

Repeatability

0.1% of rate

Flow range

0.10…39.4 ft/s (0.03…12 m/s)

Conductivity

Min. 5 μS/cm (min. 20   μS/cm for demineralized water)

Power supply

AC or optional 24V DC
AC Power Supply: 85…240V AC, 45…65 Hz
Voltage Fluctuation = ± 10% of nominal
Over Voltage = Category II
Power Consumption = 20 W
DC Power Supply (optional): 24V DC ± 10% 8 W

Display

LCD graphic display

Digital outputs

2 x open collector, 1 x   relay

Digital inputs

Yes

Analog output

0/4 – 20 mA, 0 – 10 mA

Interface

Modbus RTU communications and display for 110/220V AC (P.N. 65778-007) or 24V DC (P.N. 65778-008).
Options must be selected at time of order

Empty pipe detection

Field tunable for optimum performance based on specific application

Housing

Aluminium, IP 67

Remote version

Max. 30 m

Ambient temperature

-20 °C up to +50 °C

ModMAG-M3000-(low-res)